| ProjectSample Project — Demonstration Only | Job No.SAMPLE-001 | Client— |
| CalculationASME B31.1 Power Piping Wall Thickness Calculator | Calc byPiping Toolset (calc-core) | Checked byUNCHECKED — sample |
| Date2026-07-21 | Rev0 | BasisASME B31.1 ¶104.1.2 (also B31.5/B31.9 form) |
NPS 8 (8.625 in OD) main steam-class line at 1,000 psi. SE = 15,000 psi, y = 0.4, allowance A = 0.065 in, 12.5% mill tolerance.
| Design pressure P | 1,000 | psi |
| Outside diameter Do | 8.625 | in |
| Allowable SE | 15,000 | psi |
| Coefficient y | 0.4 | — |
| Allowance A | 0.065 | in |
| Mill tolerance | 12.5 | % |
t = P·Do / ( 2 (S·E + P·y) )
tm = t + A
torder = tm / (1 − mill tolerance)
where A is the additional thickness allowance (corrosion, erosion, threading, structural). S·E — the maximum allowable stress including longitudinal joint efficiency — and y come from the B31.1 Appendix A tables and Table 104.1.2-1 respectively, entered by you.
| t — pressure design thickness | 0.28003 | in |
| tm — minimum required | 0.34503 | in |
| Ordering thickness | 0.39432 | in |
The result values above are locked as fixture b311-wall-thickness.json, case
“NPS 8 @ 1000 psi, S=15000, E=1, y=0.4, A=0.065, 12.5% mill tol”, tolerance 0.00001, in the calc-core continuous
verification gate (see https://pipingtoolset.com/trust/validation.html). Allowable-stress and factor data are
user-supplied inputs; citations: ASME B31.1, Power Piping — ¶104.1.2, pressure design of straight pipe (Eq. 7 form). · ASME B31.1 — Appendix A allowable stress tables; Table 104.1.2-1 coefficient y — values user-supplied, not embedded. · ASME B31.5 / B31.9 — same equation form used by the Building & HVAC line with those sections' allowables.