SAMPLE
Piping Toolset — Calculation Report
generated by calc-core · 2026-07-21
ProjectSample Project — Demonstration Only Job No.SAMPLE-001 Client
CalculationASME B31.1 Power Piping Wall Thickness Calculator Calc byPiping Toolset (calc-core) Checked byUNCHECKED — sample
Date2026-07-21 Rev0 BasisASME B31.1 ¶104.1.2 (also B31.5/B31.9 form)

1 · Design inputs

NPS 8 (8.625 in OD) main steam-class line at 1,000 psi. SE = 15,000 psi, y = 0.4, allowance A = 0.065 in, 12.5% mill tolerance.

Design pressure P1,000psi
Outside diameter Do8.625in
Allowable SE15,000psi
Coefficient y0.4
Allowance A0.065in
Mill tolerance12.5%

2 · Method

t = P·Do / ( 2 (S·E + P·y) )

tm = t + A

torder = tm / (1 − mill tolerance)

where A is the additional thickness allowance (corrosion, erosion, threading, structural). S·E — the maximum allowable stress including longitudinal joint efficiency — and y come from the B31.1 Appendix A tables and Table 104.1.2-1 respectively, entered by you.

3 · Calculation

  1. Denominator: 2·(SE + P·y) = 2·(15,000 + 1,000·0.4) = 2·15,400 = 30,800 psi.
  2. Pressure design thickness: t = 1,000·8.625 / 30,800 = 0.28003 in.
  3. Minimum wall: tm = 0.28003 + 0.065 = 0.34503 in.
  4. Ordering thickness: 0.34503 / 0.875 = 0.39432 in → Sch 60 (0.406 in) covers it; Sch 40 (0.322 in) does not.

4 · Results COMPUTED

t — pressure design thickness0.28003in
tm — minimum required0.34503in
Ordering thickness0.39432in

5 · Verification statement

The result values above are locked as fixture b311-wall-thickness.json, case “NPS 8 @ 1000 psi, S=15000, E=1, y=0.4, A=0.065, 12.5% mill tol”, tolerance 0.00001, in the calc-core continuous verification gate (see https://pipingtoolset.com/trust/validation.html). Allowable-stress and factor data are user-supplied inputs; citations: ASME B31.1, Power Piping — ¶104.1.2, pressure design of straight pipe (Eq. 7 form). · ASME B31.1 — Appendix A allowable stress tables; Table 104.1.2-1 coefficient y — values user-supplied, not embedded. · ASME B31.5 / B31.9 — same equation form used by the Building & HVAC line with those sections' allowables.

SAMPLE REPORT — auto-generated from a verification fixture to show the report format. Not a project calculation. ⚠ Engineering-aid tool. Public code equations; allowable-stress and factor data are user-supplied. Results MUST be independently verified and reviewed by a qualified/licensed engineer before any design, fabrication, or operation decision.