| ProjectSample Project — Demonstration Only | Job No.SAMPLE-001 | Client— |
| CalculationExpansion Loop / Leg Sizing Calculator (Guided Cantilever) | Calc byPiping Toolset (calc-core) | Checked byUNCHECKED — sample |
| Date2026-07-21 | Rev0 | BasisGuided cantilever √(3EDΔL/kS) — Kellogg / PPI forms |
2½ in (2.875 in OD) carbon-steel line, installed at 52 °F, operating at 350 °F, 100 ft anchor-to-anchor. α = 6.7×10⁻⁶ in/in·°F, E = 29×10⁶ psi, S = 15,600 psi — the published flow-sheet example.
| Config / family | L bend, metallic | — |
| OD | 2.875 | in |
| α | 6.7×10⁻⁶ | in/in·°F |
| T0 → T1 | 52 → 350 | °F |
| Run length | 100 | ft |
| E / S | 29×10⁶ / 15,600 | psi |
ΔL = α · |T1 − T0| · L (free growth of the run)
Lgc = √( 3·E·D·ΔL / (k·S) ) (required flexible leg)
Configurations: L change-of-direction uses the full leg; Z offset takes 0.6426·Lgc (the published 4 vs 6.225 coefficient ratio, E/S-invariant); U loop proportions the developed length as W = Lgc/5, H = 2W. With E = 29×10⁶ psi and S = 15,600 psi the metallic form reproduces the published rule W(ft) = 6.225·√(ΔL·D).
| ΔL — thermal growth | 2.396 | in |
| L-bend leg | 196.0 in (16.33 ft) | — |
| Z-offset leg | 125.9 | in |
| U-loop W × H | 39.2 × 78.4 | in |
The result values above are locked as fixture expansion-loop.json, case
“PDF sheet L-bend: CS 2.875 OD, 52→350°F, 100 ft (E=29e6, S=15600)”, tolerance 0.005, in the calc-core continuous
verification gate (see https://pipingtoolset.com/trust/validation.html). Allowable-stress and factor data are
user-supplied inputs; citations: M.W. Kellogg, Design of Piping Systems — guided cantilever method (public-domain engineering method). · Published coefficient rule W = 6.225·√(ΔL·D) (L/U) and 4·√(ΔL·D) (Z) — reproduced exactly by the general form at E = 29e6, S = 15,600 psi. · PPI / Corzan CPVC practice — plastic form L = √(3·E·D·ΔL/(2·S)) with working stress at max temperature.